Features And Specifications - IBM eServer 220 xSeries Installation Manual

Hide thumbs Also See for eServer 220 xSeries:
Table of Contents

Advertisement

Features and specifications

Microprocessor:
Intel® Pentium® III
microprocessor with MMX™
technology and SIMD
extensions
256 KB* ECC, level-2 cache
(min.)
133 MHz front-side bus (FSB)
Support for up to two
microprocessors
Memory:
Standard: 128 MB*
Maximum: 4 GB*
Type: 133 MHz, ECC, SDRAM,
registered DIMMs
Slots: 4 dual in-line
Drives standard:
Diskette: 1.44 MB
CD-ROM: 48X IDE
Supports hot-swap SCSI hard
disk drives (some models)
Expansion bays:
Two 5.25-in. bays (one CD-ROM
drive installed)
Two 3.5-in. bays (one diskette
drive installed)
Three 3.5-in. slim bays available
in drive cage (some models
have a hard disk drive installed)
PCI expansion slots:
Three 33 MHz/64-bit
Two 33 MHz/32-bit
Power supply:
One 330 watt autosensing (115-230 V
ac)
Table 1. Features and specifications
2
IBM® xSeries 220: Installation Guide
Table 1 provides a summary of the features and specifications for your xSeries 220
server.
Video:
S3 video controller (integrated
on system board)
Compatible with SVGA and
VGA
8 MB SDRAM video memory
Size:
Height: 470 mm (18.5 in.)
Depth: 508 mm (20 in.)
Width: 165 mm (6.5 in.)
Weight: approximately 19.5 Kg
(43 lb.) when fully configured
or 15.9 Kg (35 lb.) minimum
Integrated functions:
Ultra160 SCSI low voltage
differential (LVD) controller
One 10BASE-T/100BASE-TX
Intel Ethernet controller on the
system board
Two serial ports
Parallel port
Two Universal Serial Bus
(USB) ports
Keyboard port
Mouse port
IDE controller port
Video port
Acoustical noise emissions:
Sound power, idling: 5.9 bel
maximum
Sound power, operating: 6.1
bel maximum
*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB
equals approximately 1000000000 bytes.
Environment:
Air temperature:
— Server on: 10º to 35º C (50.0º
to 95.0º F). Altitude: 0 to 914
m (2998.7 ft)
— Server on: 10º to 32º C (50.0º
to 89.6º F). Altitude: 914 m
(2998.7 ft) to 2133 m (6998.0
ft)
— Server off: 10º to 43º C (50.0º
to 109.4º F). Maximum
altitude: 2133 m (6998.0 ft)
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 341 Btu
(100 watts)
Maximum configuration: 1604
Btu (470 watts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA),
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA

Advertisement

Table of Contents