Installation Outdoors/Indoors; Installation On Floors Constructed Of Combustible Materials - Pentair Pool Products MiniMax NT Series Service Manual

Hide thumbs Also See for MiniMax NT Series:
Table of Contents

Advertisement

Installation -
The heater should not be installed closer than 6 inches to any
fences, walls or shrubs at any side or back, nor closer than 18
inches at the plumbing side. A minimum clearance of 24 inches
must be maintained at the front of the heater. The heater should
be installed at least 5 feet away from the pool or spa.
24"
Figure 1.
INSTALLATION ON FLOORS CONSTRUCTED
OF COMBUSTIBLE MATERIALS
The heater may be placed on a "combustible floor"
using the method listed below:
a) The heater must be installed on a non-combustible floor
and at least six inches from any combustible material or
wall. Construct a non-combustible base from masonry
blocks as illustrated in Figure 2.
BASE FOR USE ON COMBUSTIBLE FLOORS
SHEET METAL
BLOCKS
Figure 2.
P/N NTSM03
Outdoors/Indoors
6"
6"
18"
HOLLOW MASONARY BLOCKS, NOT LESS THAN 4" THICK
(LAID WITH ENDS UNSEALED AND JOINTS MATCHED
FOR AIR CIRCULATION). COVER BLOCKS WITH
24 GA. (MIN.) GALVANIZED SHEET METAL.
IMPORTANT!
Under certain conditions, "heavy rains or unusually high winds",
it may be necessary to install an outdoors vent. In this situation,
use vent adaptor P/N 460507 and outdoor vent P/N 471357.
From the point where the flue products leave the heater, that point
MUST be a minimum of (4) feet below, and (4) feet horizontally from
or (1) foot above any door, window or gravity inlet to a building.
OUTDOOR INSTALLATION
VENTING GUIDELINES
INDOOR INSTALLATIONS
The heater must be placed in a suitable room on a non-combustible
floor or on a non-combustible base and in an area where leakage
from heat exchanger or water connections will not result in
damage to the area adjacent to the heater or the structure. When
such locations cannot be avoided, it is recommended that a
suitable drain pan with adequate drainage, be installed under the
heater. The pan must not restrict air flow.
Installations in basements, garages, or underground structures
where flammable liquids may be stored must have the heater
elevated 18 inches from the floor using a non-combustible base.
The following minimum clearances from combustible materials
must be provided.
Side
Water Connection
18 in.
Remaining
6 in.
Ceiling Clearance
*To ceiling or roof.
CAUTION
Chemicals should not be stored near the heater installation.
Combustion air can be contaminated by corrosive chemical
fumes which can void the warranty.
NOTE
3'
4' Min. Below
4'
Figure 3.
Front
Back
24 in.
-
-
6 in.
-
-
-
Rev. B 2-11-04
6
Top
-
-
18 in.*