Outdoor Unit
Step
2. Dismounting the fan
motors
1
Disconnect the two fan
motor relay connectors
from the PCB in the
electrical box.
2
The fan motor leads
are hooked in some
locations: one hook for
the upper fan and two
for the lower fan.
Undo the lead tie-
3
wraps first and then the
lead clamp off the
partition board.
4
Disconnect the earth
wire from the upper-
motor mount.
Undo the clamp.
5
Remove the four
6
screws from the fan
motor. Then dismount
the fan motor.
330
Procedure
Si18-201
Points
"
In disconnecting the
connectors, do not pull the
leads, but hold the
connectors and press the
hooks.
"
Precaution in mounting the
motors:
Be sure to secure the motor
leads with the clamps.
Otherwise the leads may get
caught by the fans.
"
In setting up the fan, put the
partition board piece
between the tie-wraps A and
B and secure the lead.