Si18-201
"
"
Others
1.1.22
Good Sleep Cooling Control
For FTK(X)25/35 J
The function to create deep sleeping and to offer good sleep by altering the set temperatures in
certain intervals to give temperature variation to a living space based on "1/f temperature
Series Only
fluctuation" principle, in case of going to bed while air conditioner keeps operating in cooling
Outline
mode.
Processing
Set temp.+1˚C
the set temperature
before the good sleep
cooling
Entering the good
sleep control (ON)
Notes:
1. Each timer's counting/stop is not related to a thermostat ON/OFF.
2. When the sleeping control works by the OFF timer, the shift from the set temperature should
3. While operation with the good sleep cooling control and off-timer setting, if the signal of the
4. When the good sleep cooling control is on while a normal operation with a OFF-timer is
5. Fan speed will change by the alteration of the set temperature by 1°C at the automatic fan
6. The function of the good sleep cooling is cancelled, when the good sleep cooling operation
7. The priority order for each function is ; 'Powerful', 'Intelligent eye', 'Good sleep', and 'Night
Main Functions
Since the set temperature is shifted by 2°C higher for 40 minutes, compressor speed
becomes low and can realize energy saving operation. But as thermostat is prone to be off
by the fact that the set temperature has been shifted, the thermostat-off action is prohibited
in 40 minutes so as to prevent this phenomena.
After this 40 minutes, the prohibition of the thermostat-off is cancelled and it can realize the
conditions to conduct thermostat-off depending on the room temperature. In or after this forty
minutes, if the sensor detects human motion detection signal, it turns on "Human detection
LED" and let the set temperature and the fan speed return to the original set point, keeping a
normal operation.
The dry operation can't command the setting temperature with a remote controller, but
internally the set temperature is shifted by 1°C.
20
17
60
21
63
be just 1°C with this control function.
(The temperature shift of the normal OFF-timer will not be carried out. However, the passed
time should be remembered since the OFF-timer was set.)
good sleep cooling OFF signal comes, the level of the set temperature shift should be set
corresponding to the same with an existing value in accordance with the passed time since
the OFF-timer was set.
going on, once returning to the original criterion which doesn't shift the timer's set
temperature, and the shift alteration at every sequence by 1°C is carried out in accordance
with the value above mentioned.
speed operation mode, and it causes an alteration of fan noise. So, the fan tap should be
fixed at L tap position during the good sleep cooling even at the auto fan speed operation.
is off or operation OFF command is received or also the operation mode changes to the
mode except cooling.
set mode'.
one cycle
63
41
22
63
Main Functions
[Unit: min]
repeating
63
27
20
60
20
(RL021)
91