Actuator Scrub Deck Removal/Replacement - Windsor Saber Cutter SCX326 Operating Instructions Manual

Walk behind scrubber
Hide thumbs Also See for Saber Cutter SCX326:
Table of Contents

Advertisement

Maintenance
Actuator Scrub Deck Removal/
Replacement
FOR SAFETY: Before leaving or servicing
machine, stop on a level surface, turn off machine
and set parking brake (If option is installed).
1. Remove front cover.
2. Remove the two nuts below the scrub deck that
attach the actuator bracket.
3. Remove clevis pin and rue ring from lower bracket
of actuator, make sure not allow actuator bracket to
rotate.
4. Disconnect actuator from wiring harness.
5. Remove upper clevis pin and rue ring from actuator
bracket.
6. Reverse steps to install.
30
Scrub Deck Actuator Adjustment
The actuator will need to be adjusted when replaced.
To adjust the actuator:
1. While holding actuator barrel to prevent it from
spinning, apply power to the actuator such that it is
fully extended. Positive power to white wire, and
negative/ground to black. Limit switch within
actuator will stop it.
2. Turn barrel out one or more full turns to assure that
when it is retracted it will not bind against itself.
3. While holding actuator barrel to prevent it from
spinning, apply power to the actuator such that it is
fully retracted. Positive power to black wire, and
negative/ground to white wire. Limit switch within
actuator will stop it.
4. With actuator fully retracted, turn barrel in until it
touches the base of the threaded shaft.
5. At the bottomed out position, turn the barrel out
6. 1 1/2 turns, then enough more to allow connection
to lift linkage.
7. Connect actuator to lift linkage.
8. Check travel of actuator during operation.
86039100 CUTTER 36V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents