A. Gas Control System (continued)
3.
Temperature Adjustment
a) Water too hot:
1) Thermostat set too high. Adjust temperature to lower selection accordingly.
2) Check Orifice size, check gas pressure.
b) Not enouah hot water:
1) Thermostat set too low. Adjust temperature to higher selection.
2 Misalignment of main burner
-
adjust and realign elbow on burner tube.
3
I
Obstruction in main burner or air intake
-
clean accordingly.
4)
Main burner orifice too small or clogged
-
remove and clean or replace.
5) Thermostat gas control out of calibration
-
replace.
B. Gas Ignition System
1. Reignitor
A reignitor eliminates the need for matches to light the pilot. It will maintain a pilot flame under
windy conditions, and has an alarm which willsound when the pilot flame is extinguished or if the
LP gas supply is turned off. It is available on all pilot models. A reignitor can be field installed.
2. Installation and Operation
See Field Instructions for Reignitor Control.