Q-Beam 260-LED QRG
AC Power
Fuse
Replacement
Mounting
Product
Mounting
Diagram
Control Panel
Description
Programming
Password
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
1) Disconnect the unit from the power outlet.
2) With a flat head screwdriver, wedge the fuse holder out of its housing
and remove the blown fuse from its holder.
3) Replace the blown fuse with a fuse of the exact same type and rating.
4) Insert the fuse holder back in its place, and reconnect power.
Before mounting this product, read the safety notes at the beginning of this
guide and on page 2 of the product's user manual. Then, follow the
mounting procedure indicated in the Setup chapter of the user manual.
Button
Function
Exits from the current menu or function
<MENU>
Enables the currently displayed menu or sets the currently
<ENTER>
selected value into the selected function
Navigates upwards through the menu list and increases the
<UP>
numeric value when in a function
Navigates downwards through the menu list and decreases
<DOWN>
the numeric value when in a function
For details on how to program this product, please refer to the product's
user manual.
After being prompted to enter the password, press:
<UP>, <DOWN>, <UP>, <DOWN>, and <ENTER>
C Clamps (not included)
Safety cable (included)
Omega brackets (included)
Overhead
Mounting
Floor
Mounting