NOTE
COOL: When the room temperature is 4 °F higher than the set temperature, the set temperature may not be changed
since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until
the room temperature drops to within 4 °F of the set temperature and then change the set temperature.
HEAT: When the room temperature is 4 °F lower than the set temperature, the set temperature may not be
changed since the air conditioner is operating to reach the target (set) temperature. In this case,
please wait until the room temperature rises to within 4 °F of the set temperature and then change the
set temperature.
Details of display on the indoor unit
The operation indicator at the right side of the indoor unit indicates
the operation state.
MSZ09UN
Lighted
Operation
Not lighted
Indicator
Operation indicator lamp
MSZ09UN
Indication
This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.
This shows that the room temperature is approaching the
target temperature.
MSZ12UN
Indication
This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.
This shows that the room temperature is approaching the
target temperature.
Description of "AUTO RESTART FUNCTION"
I These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power.
I If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
I If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.
I If the unit is operated in "I FEEL ..." mode before power failure, the operation is not stored in the memory. In "I FEEL ..."
mode, the operation is decided by the initial room temperature at (re)start.
I Since the air conditioner has been shipped from the factory with the COOL mode saved in the memory for auto restart
function, it starts cooling operation when the user turns on the main power for the first time after installation.
MSZ12UN
Lighted
Operation Indicator
Not lighted
Operation state
Operation state
Difference between target
temperature and room temperature
About 4 °F or more
About 4 °F or less
Difference between target
temperature and room temperature
About 4 °F or more
About 4 °F or less