LG DLHX4072 series Owner's Manual page 25

Hide thumbs Also See for DLHX4072 series:
Table of Contents

Advertisement

Available languages

Available languages

Connecting electric dryers (cont.)
USA only
WARNING
colored wire should be connected to same color screw.
color screw in block. Failure to follow these instructions
may result in a short or overload.
prohibit grounding through the neutral conductor.
Four-wire connection for electric dryers: Direct wire
ends of the three shorter wires into a hook shape.
the dryer. Install a UL-listed strain relief into the power cord
through the strain relief.
UL-Listed
Cord
Ground Wire
Terminal
UL-Listed
Strain Relief
INSTALLATION INSTRUCTIONS
cable.
reinstallation of the dryer.
screw to the center screw of the terminal block. Attach the two
hot leads of the power cable to the outer terminal block screws.
Attach the white neutral wire to the center terminal block
screw. Attach the power cable ground wire to the green ground
screw.
block access cover.
Hot
Neutral
Ground
Screw
Power Cord
Ground Wire
25
conductor
. Reinstall the terminal
Hot
White Wire
moved from
Ground Screw

Advertisement

Chapters

Table of Contents
loading

Table of Contents