O P E R A T I O N A N D S E R V I C E I N F O R M A T I O N
Read all of manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notes, Cautions and Warnings
Provide Protection From Elements
Do Not Block Louvered Airways
NEMA 15 - 5R Grounded AC Receptacle
110 - 120 VAC. Dedicated 15 AMP Circuit
Locations outside the US and Canada: Reference
appropriate local electrical code and charger manu-
facturer recommendations for AC power requirements
Ref Pci 1

Fig. 2 Proper Charger Installation

rain and sun protection must be provided (Ref. Fig. 2 on
page 2). A dedicated circuit is required for the charger.
Refer to the charger manual for appropriate circuit pro-
tection. The charger may remain plugged in to the AC
outlet. To charge the vehicle, refer to the instruction
labels on the charger. Insert the polarized DC plug com-
pletely into the vehicle receptacle (Ref. Fig. 3 on page 2).
Front of
Vehicle
Charger
Receptacle
Ref Crl 1
Fig. 3 Charger Receptacle Location
The charger will automatically start a few seconds after
plug insertion. The charger will automatically stop when
batteries are fully charged and the DC plug can be
removed to permit use of the vehicle.
Looping the DC cord through the steering
wheel when charging, serves as a good
reminder to store the cord out of the way when finished with
charging. The DC plug can be damaged by driving over or
catching the cord on the vehicle when driving away.
Page 2
cal shock or electrocution, be sure that the charger
plug is not damaged and is inserted into a grounded
receptacle.
The power (AC) cord is equipped with a grounded
plug, do not attempt to pull out, cut or bend the
ground post.
The charging (DC) cord is equipped with a polarized con-
nector which fits into a matching receptacle on the vehi-
cle.
The power (AC) cord is equipped with a grounded plug.
Do not attempt to remove, cut or bend the ground post.

On-board Charger

The on-board charger is located under the seat on the
driver side of the vehicle (Ref. Fig. 4 on page 2). It is
wired directly to the batteries, only requiring it be plugged
into a dedicated 15 amp AC outlet to be operational.
When charging cycle is complete, replace cord around
charger handle in area provided.
the charger.
Vehicle controls and indicators consist of:
Owner's Manual and Service Guide
!
!
Ref Obc 1
Fig. 4 On-board Charger
If vehicle is to be charged with a non E-Z-GO
charger, refer to the instructions supplied with

CONTROLS AND INDICATORS

key/light switch
direction selector
state of charge meter