Thermal
Limit Switch
Pressure
Switch
Pressure
Vacuum
Injector
• Output Rating - 125,000 Btu/Hr (131,882 kJ/Hr)
• Fuel Consumption - 1.4 Gal/Hr (5.2 Liters/Hr), 5.8 lb/Hr (2.6 kg/Hr)
• Propane Vapor Fuel Only
• Manifold Pressure - 10" (25.4 cm) WC
• Supply Pressure To Regulator: Minimum (for purposes of input adjustment) 10 psi (69 kPa),
Maximum - Tank Pressure
• Regulator Outlet Pressure - 11" wc
• Electric Input - 120 V/60 Hz
• Amperage - Start 7, Run 3.5
• Load - 10 amps on receptacle
• Hot Air Output (Approx) - 1000 CFM (28.3 m
• Motor - 1,100 RPM, 1/4 HP
• Ignition - Electronic Direct Spark Ignition (D.S.I.)
• Ignitor Gap - 0.10"/0.12" (2.5/3.0 mm)
120942-01E