Carrier OBL098 Installation Instructions Manual page 14

Low boy oil furnace
Hide thumbs Also See for OBL098:
Table of Contents

Advertisement

Table 8: Airflow Data, Models with 1/2 HP ECM motors
SW 1- H EAT
DIP switch position
A
(1=OFF, 2=OFF)
B (1=ON,2=OFF)
*C (I=OFE
2=ON)
D (1=ON,2=ON)
HEAT INPUT
/USGPH)
0,70
0,55
0_55
CFM with SW3-ADJ
CFM with SW3-ADJ
DIP switch position A
DIP switch position B
1260
1385
1050
1155
850
935
Same value as DIP switch position A
CFM with SW3-ADJ
DIP switch position C
1135
945
765
SW2- COOL
DIP switch position
A
(1=OFF, 2=OFF)
B (1=ON,2=OFF)
C (1 =OFF, 2=ON)
D (1=ON,2=ON)
A/C size
(TON)
3,0
2,5
2,0
1,5
CFM with SW3-ADJ
DIP switch position A
900
750
600
450
CFM with SW3-ADJ
DIP switch position B
990
830
660
495
CFM with SW3-ADJ
DIP switch position C
810
675
540
405
A/C size
(TON)
3,0
2,5
2,0
1,5
InCooling-Dehumidification mode,
SW2- COOL
DIP switch position
A
(1=OFF, 2=OFF)
B (1=ON,2=OFF)
C (1 =OFF, 2=ON)
D (1=ON,2=ON)
CFM with SW3-ADJ
DIP switch position A
1200
1000
800
600
CFM with SW3-ADJ
DIP switch position B
1320
1100
880
660
CFM with SW3-ADJ
DIP switch position C
1080
900
720
540
with no 24 VAC input to DH, the CFMs are reduced by 15%.
The CFMs shown are reduced by 20% if there is 24 VAC input to Y1 (Slow speed of 2-speed compressor)
SW4- DEALY
A
(1=OFF, 2=OFF)
B
(1=ON, 2=OFF)
*C (1 =OFF, 2=ON)
D (1 =ON, 2=ON)
HEAT INPUT
0,7
0,55
0,55
All
PreRun On-Delay
13% -45 sec.
13% -45 sec.
13% -60 sec.
13% -30 sec.
ShortRun On-Delay
19% - 30 sec
19% - 60 sec
13% - 60 sec
100% - 0 sec
Off-Delay
38% - 3 min.
38% - 3 min.
38% - 3 min.
100% - 2 min.
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to minimize the
distributon of cool air in the system and then runs up to normal speed.
Off Delay is the time required to cool down the heat exchanger with low CFMs, to minimize cool draft in the
air distribution system.
No adjustment
A/C size
PreRun On-Delay
ShortRun On-Delay
Off-Delay
required
CFM Level - Time
CFM Level - Time
CFM Level - Time
All
No Delay
No Delay
100% - 90 sec.
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to minimize the
distributon of cool air in the system and then runs up to normal speed.
Off Delay is the time required to cool down the coil (heating mode) with low CFMs, to mimimize cool draft
in the air distribution system.
Alternate position for 0.55 input