4-8. Gun Duty Cycle And Overheating
100%dutycycle
Continuous Welding
Overheating
4-9. Generator Power Curve
300
250
240 Volt
200
150
100
50
0
0
20
60%dutycycle
6 Minutes Welding
0
15
Minutes
120 Volt
40
60
80
AC Amperes
.
Complete Parts List available at www. MillerWelds.com
See Section 4-3. Specifications for
amperage rating and duty cycle.
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
4 Minutes Resting
A or V
OR
Reduce Duty Cycle
The ac generator power curves
show the generator power available
in amperes at the receptacles.
100
120
sduty1 5/95
233 242
OM-228 042 Page 15