Miller Electric 500DX R Owner's Manual page 40

Engine driven welding generator
Table of Contents

Advertisement

Trouble
B. Auxiliary Power
Trouble
No
output
at
auxiliary
receptacles.
High or low output at auxiliary power
receptacles.
No or low output at optional auxiliary
power plant.
High output at optional auxiliary power
plant.
C. Engine
Trouble
Engine does not start.
Engine suddenly stops.
Battery discharges between uses.
OM-129 647 Page 36
Repair or replace remote control device.
Have Factory Authorized Service Agent check optional CV regulator board PC2.
power
Reset receptacle circuit breakers.
Have Factory Authorized Service Agent check brushes and slip rings, and optional field current regula-
tor board PC1.
Check engine speed, and adjust if necessary (see Section 7-5).
Check connections to auxiliary power plant (see Section 6-3).
Check engine speed, and adjust if necessary (see Section 7-5).
Place A/V Control switch in Panel position, or place switch in Remote position and connect remote con-
trol to Remote A/V Control receptacle RC3 (see Sections 4-9 and 5-1).
Check fuses F1, F2, and F3 and replace as necessary (see Section 6-3).
Set optional remote control at maximum (see Section 4-9 or 4-10).
Place optional Output/Contactor Control switch in On position, or place switch in Remote position and
connect remote contactor to optional Remote 14 receptacle RC3 or terminal strip 2T (see Sections 4-10
and 4-11).
Place optional CC/CV switch in CC position (see Section 5-3).
Have Factory Authorized Service Agent check brushes and slip rings, and optional field current regula-
tor board PC1.
Check engine speed, and adjust if necessary (see Section 7-5).
Have Factory Authorized Service Agent check optional field current regulator board PC1.
Check fuel level (see Section 4-5).
Open fuel valve (see Section 4-5).
Check battery and replace if necessary.
Check blower fan V-belt according to engine manual. Safety shutdown stops engine if belt is broken
or loose (see Section 7-8).
Check engine Start button and replace if necessary.
Check engine charging system according to engine manual.
See engine manual.
Check blower fan V-belt according to engine manual. Safety shutdown stops engine if belt is broken
or loose (see Section 7-8).
See engine manual.
Clean top of battery with baking soda and water solution; rinse with clear water.
Recharge or replace battery if necessary.
Remedy
Remedy
Remedy