Miller Electric 145 DXR, 145 Owner's Manual page 34

Engine driven welding generator
Table of Contents

Advertisement

Trouble
Low output at generator power ac
receptacles.
Erratic output at generator power ac
receptacles.
receptacles
C. Engine
Trouble
Engine will not crank (DX models only). Check and replace ignition fuse (see engine manual).
Engine will not start.
Engine stopped during normal
operation.
Battery discharges between uses (DX
models only).
Unstable or sluggish engine speeds.
OM-4417 Page 30
Check Weld Output control setting.
Check engine speed, and adjust if necessary (see Section 8-3 or 8-4). Open circuit voltage is reduced
as engine speed drops.
Check fuel level.
Have Factory Authorized Service Agent check connections at terminal block 1T.
Check receptacle supplementary protector, wiring, and connections.
Check throttle linkage for smooth, non-binding operation.
Service air cleaner according to engine manual.
Check engine speed, and adjust if necessary (see Section 8-3 or 8-4).
Check battery voltage.
Check battery connections and tighten if necessary.
Have Factory Authorized Service Agent check engine ignition circuit.
Check fuel level (see Section 5-4).
Move choke control to correct position (see Section 6-1 or 6-3).
Open fuel valve (see Section 5-4). Close fuel valve before moving unit or carburetor may flood and make
starting difficult.
Check battery voltage (DX models only).
Check battery connections and tighten if necessary (DX models only).
Check oil level (see Section 5-4). Engine stops if oil level is too low. Refill crankcase with proper viscosity
oil for operating temperature.
Have Factory Authorized Service Agent check low oil level shutdown switch.
Check fuel level (see Section 5-4).
Open fuel valve (see Section 5-4). Close fuel valve before moving unit or carburetor may flood and make
starting difficult.
Check oil level (see Section 5-4). Engine stops if oil level is too low.
Clean battery, terminals, and posts with baking soda and water solution; rinse with clear water.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check engine battery charging circuit and connections according to engine manual.
Check engine speed, and adjust if necessary (see Section 8-3 or 8-4).
Check throttle/governor linkage for smooth, non-binding operation.
Tune-up engine according to engine manual.
.
Complete Parts List available at www.MillerWelds.com
Remedy
Remedy

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blue star 145Blue star 145 dx

Table of Contents