Section 4 - Installation; Selecting A Location And Moving Rack; Installing Welding Power Source Onto Rack - Miller Electric XMT 4-Rack Owner's Manual

Mounting rack for up to four xmt 300 welding power sources with auto-link and requiring 230/460 volt input power
Table of Contents

Advertisement

4-1. Selecting A Location And Moving Rack

WARNING
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Disconnect input power conductors from de-
energized supply line BEFORE moving rack.
FIRE OR EXPLOSION can result from
placing unit on, over, or near com-
bustible surfaces.
Do not locate unit on, over, or near combustible
surfaces.
Do not install unit near flammables.

4-2. Installing Welding Power Source Onto Rack

1
OM-815 Page 6
SECTION 4 – INSTALLATION
1
Figure 4-1. Location And Movement Of Rack
As Shipped
2
3
Figure 4-2. Welding Power Source Installation
FUMES can be hazardous; LACK OF
F RESH AI R AND PRO PER VEN-
TILATION can be harmful.
Do not breathe welding fumes.
Place unit only where there is a good fresh air supply
and proper ventilation.
FAL L I NG EQ UI PM ENT can cau se
serious personal injury and equipment
damage.
Move unit with crane or fork lift vehicle of adequate
capacity.
2
6
In Use
4
5
swarn11.1* 3/93
1
Lifting Eye
Use lifting eye to move unit.
2
Lifting Forks
If using lifting forks, be sure forks
are fully inserted.
ST-158 366
1
Bracket
Remove user-supplied bolt or lock
if applicable.
2
Securing Bolts
Loosen.
3
Front Bracket
Swing end near rack center away
from rack.
4
Rear Bracket
5
Securing Bracket
Place welding power source on
rack so rear is against rear bracket
and securing bracket is centered
between welding power source
feet.
Swing front bracket back into
position.
Tighten securing bolts.
Reinstall user-supplied bolt or lock
if applicable.
6
Weld Cable Hanger
ST-158 332 / S-0548 / ST-151 268-A

Advertisement

Table of Contents
loading

Table of Contents