WDV Series Gas Fireplace
clearances tO cOMBustIBles
Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring,
the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.
54" Minimum
Ceiling
12" Max.
Depth
6" Min.
FP41
Figure 4 -
Ceiling and Sidewall Clearances
FP2421
mantel clearances
Mantel clearances
nOte: the combustible area above the facing must not protrude more than 3/4" from the
facing. If it does, it is considered a mantel and must meet the mantel requirements listed in
this manual.
8
2
/
" Max Depth
1
2
12" Min.
From Opening
6" Min.
From Opening
5 "
Min. to Combustibles
Wall
12"
6"
12"
9"
6"
Top of Fireplace
Opening
side View
FP43
1"
2 "
Side of Fire-
place Opening
top View
Figure 5 -
Mantel clearances
FP2423
mantel leg
clearances
Stud
Insulation
Board
Standoff
2
1
/
"
2
FP4
FP2422
mantel clearances
1 "
3
"
4
"
45°
3"
5"
6"
78D0011