Appliance Dimensions; Installation - Miele DA 289-4 Operating And Installation Instructions

Miele ventilation system operating and installation instructions
Table of Contents

Advertisement

1) and 2)
Cut out area in wall or ceiling for
entrance of 6" (150 mm)
ductwork or 5" (125 mm) ductwork with
a reducing collar.
Do not install this exhaust hood over
cooktops burning solid fuel.
Provided a larger distance is not
given by the manufacturer of the
cooktop, follow the recommended
minimum safety distances between
a cooktop and the bottom of the
grease filter of 30" (762 mm).
If local building codes require a
greater safety distance, follow their
requirement.
Follow the safety distances
recommended by the cooktop
manufacturer in their installation and
operating instructions.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
See "IMPORTANT SAFETY
INSTRUCTIONS" for further
information.

Appliance dimensions

Distance between cooktop and
hood (S)
^ To observe the safety distance and
ensure an optimum function and use
of the hood, a distance of S = 14
(365 mm) between the cooktop and
the lower edge of the glass pane is
recommended.
^ If the hood is fitted flush to the
ceiling, the sum of
S + H + Workspace
should not exceed the room height.
Standard unit height H
37 7/8" - 51 7/8"
(960 - 1320 mm)
To fit the lower chimney section, the
distance between the top of the
chimney and the ceiling must be at
7
least
/
" (20 mm).
8
3
/
"
8
29