Sharp LC-32D65E Service Manual page 58

Hide thumbs Also See for LC-32D65E:
Table of Contents

Advertisement

LC-32D65E/RU, LC-37D65E/RU
2) Inverter/Lamp failure details (Power red LED flashes once and OPC (preset) LED flashes)
Error type
OPC (preset) LED operation (1 cycle)
H: On
Lamp failure
Flashes once
L: Off
3) Power failure details (Power red LED flashes twice and OPC (preset) LED flashes)
Error type
OPC (preset) LED operation (1 cycle)
H: On
PS_ON
AC_DET fail-
ure Flashes
once
L: Off
H: On
D_POW
Main 12V fail-
ure Flashes
twice
L: Off
D_POW
H: On
Digital 3.3V
Failure
Flashes 3
L: Off
times
4) Communication failure details (Power green LED flashes once and OPC (preset) LED flashes)
Error type
OPC (preset) LED operation (1 cycle)
H: On
Initial communi-
cation reception
failure Flashes
once
L: Off
Start-up confir-
H: On
mation recep-
tion failure
Flashes twice
L: Off
Regular commu-
H: On
nication failure
Flashes 3 times
L: Off
H: On
Other communi-
cation failure
Flashes 5 times
L: Off
5) Other failure details (Power green LED flashes twice and OPC (preset) LED flashes)
Error type
OPC (preset) LED operation (1 cycle)
H: On
Monitor temper-
ature failure
Flashes once
L: Off
H: On
Main failure
Flashes 3 times
L: Off
Note: Pins are monitor microprocessor pins unless otherwise specified (IC2003).
ERR_PNL(40pin): Abnormal L. Confirmed after 5 consecutive detections at 1 second
intervals (detected only when the backlight is on).
Note that after five detection counts, the lamp cannot be activated except in the moni-
toring process. (For the first time, only the inverter is reset, and error OFF is not acti-
vated.)
Accumulated counts are cleared to 0 when the setting in the adjustment process is
made, when AC_ON is performed with [CH_DOWN] and [VOL_UP] on the unit down
or after continuous illumination for 3 minutes.
Note: Pins are monitor microprocessor pins unless otherwise specified (IC2003).
AC_DET(72pin: Abnormal (L).
If error is detected during start-up or operation, the power is turned on again by inter-
rupt handling (instantaneous blackout processing).
DET_12V(34pin): Abnormal (L). Main 12V is not applied.
If error is detected during start-up or operation, the power is turned on again by polling.
DET_D3V3(35pin): abnormal (L). Digital 3.3V is not applied.
If error is detected during start-up or operation, the power is turned on again by polling.
Note: Basically, debug print logs are analyzed or communication logs
are analyzed by a bus monitor.
Initial communication from the main CPU is not received. (Request for the
monitor model No. is not received.)
→ Communication line failure or main CPU start-up failure
Start-up reason confirmation from the main CPU cannot be received. (Start-
up communication until start-up reason notification command is not
received.)
→ Main CPU start-up failure or monitor microprocessor reception failure
Regular communication that is performed at 1 second intervals in the nor-
mal operation is interrupted.
→ Main CPU operation failure or monitor microprocessor reception failure
When a request (PM_REQ=H) is sent from the main microprocessor, the
request command is not output from the main CPU, etc.
→ Main CPU operation failure or monitor microprocessor reception failure
Note: Pins are monitor microprocessor pins unless otherwise specified
(IC2003).
If the panel temperature is 60°C or more for 15 seconds or more in a row, CAUTION
appears on the OSD (flashes in red in the lower right screen).
If the panel temperature is 60°C or more for 25 seconds or more in a row, error
standby is activated.
(MONITOR MAX TEMP on page 13/16 of the adjustment process: Change of tem-
perature failure AD value): Thermistor
Main microprocessor detection error (CPU temperature error, etc.)
Details are displayed on page 1/16 of the adjustment process for the main micropro-
cessor.
4 – 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-32d65ruLc-37d65eLc-37d65ru

Table of Contents