13.

Adjusting the thread trimmer -900/56

06
13

Engaging solenoid

.06.01
Requirement
1. Mounting bracket 1 must be in the middle of its adjusting range and parallel with the
right-hand edge of the mounting bracket.
2. When the thread trimmer is in its resting position the core of solenoid 3 must protrude
from the solenoid housing by about 4 mm.
Fig. 11 - 18
Re-position bracket 1 (screw 2) according to Requirement 1.
Re-position solenoid 3 (screw 4) according to Requirement 2.
4 mm
4
3
1
2