Honeywell MS2320 Installation And User Manual page 49

Stratosh scanner / avery scale
Hide thumbs Also See for MS2320:
Table of Contents

Advertisement

S
O
CALE
PERATION
C
ALIBRATION
Bar Code Calibration Procedure without Remote Display*
5.
Reinstall the platter and power up the unit.
See power source caution statement on page 8 of this manual.
6.
Enter bar code calibration mode. Use the vertical window to scan the following bar code. The scanner will beep once
as it enters the bar code calibration mode and the calibration utility will start.
Bar Code Calibration Mode
³ 9 9 6 0 0 0
If a razz tone sounds, an error has occurred. Refer to Diagnostic Indicator Display; Error Codes starting on
page 30 for additional information.
7.
Make sure there is no load on the scale platter. The white LEDs will be used to indicate the current step in the calibration
process.
8.
Calibrate a zero load. The white LEDs will blink once periodically. Wait 8 to 10 seconds for scale stability then press the
beeper volume switch one time. The beeper will beep one time indicating that the Cal 1 value has been stored.
* These procedures are for MS2320 StratosH Scanner/Avery Scale models only
Figure 54. Platter Installation and Power Up
Figure 55. Entering Bar Code Calibration Mode
Figure 56.
.