Full Speed Usb; Ibm Oem; Serial Emulation Mode; Keyboard Emulation Mode - Honeywell MS2320 Installation And User Manual

Stratosh scanner / avery scale
Hide thumbs Also See for MS2320:
Table of Contents

Advertisement

I
NSTALLATION
C
I
(I
ABLE
NSTALLATION
F
S
USB
ULL
PEED
The following steps describe how to properly install the cables for a Full Speed USB StratosH application. The scanner/scale
must then be configured to match the host's USB parameters. Cable installation alone does not guarantee that the StratosH
will communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide (
MS2xxx Stratos Series Configuration Addendum (
1.
Turn off the host system.
2.
Plug the 10-pin RJ45 end of the USB interface cable (
labeled, Scanner USB to Host, on the bottom of the StratosH. Refer to Figure on page 19.
3.
Connect the other end of the USB interface cable to the appropriate USB port on the host device.
Before continuing verify that the USB interface cable is connected to the appropriate socket on the scanner. An
incorrect cable connection can cause communication problems or potential damage to the scanner and/or terminal.
Manufacturers Note: Plugging the scanner into the USB port of the host does not guarantee that scanned
information will appear at the host. A software driver and correct configuration setting are also required for proper
communication to occur. When using the RS232/Full Speed USB/RS485 (-121) interface, the USB and RS485
interfaces are not active at the same time.
Steps 4 and 5 are for dual cable interfaces where the scale and the scanner connect to the host with their own separate
communication cables. Skip to step 6 for a single cable interface where the scale and scanner connect to the host with a
single cable.
4.
Plug the dual interface cable (
the StratosH.
5.
Connect the other end of the dual interface cable (
scale device.
6.
Plug the optional remote display cable (
the bottom of the StratosH.
7.
Plug the external power supply (
StratosH.
Specifies international connection. See Optional Accessories in the Introduction section of this guide for a complete listing.
xxx*
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
Honeywell recommends using a switched AC outlet. The switch should be located on the operator's side of the
checkout counter in close proximity to the StratosH to facilitate calibration and service of the unit.
8.
Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
S
)
NTERFACE
PECIFIC
57-57000x-N-3) into the 10-pin socket labeled, Scale RS232 to Host, on the bottom of
PN
46-00248x or 46-00249x) into the 10-pin socket labeled, Scale to Display, on
PN
46-46
) into the 3-pin Molex socket labeled, DC Power In, on the bottom of the
xxx*
PN
00-02034x).
PN
57-57200x-N-3 or 57-57006x-N-3) into the 10-pin socket
PN
57-57000x-N-3) to the appropriate communication port on the host's
PN
00-02407x) and the
PN
17

Advertisement

Table of Contents
loading

Table of Contents