Hilti TE 70-D/AVR Operating Instructions Manual page 7

Hide thumbs Also See for TE 70-D/AVR:
Table of Contents

Advertisement

Available languages

Available languages

2.2 Chuck
TE‑Y (SDS max) quick-change "click" chuck
2.3 Switches
Speed control switch for smooth starting
Combihammer function selector switch: Hammer drilling, chiseling, chisel adjustment (24 positions – depends on
version)
Selector for full or reduced (50%) power (depends on version)
Control switch locking mechanism which can be locked for chiseling (depends on version)
2.4 Grips
Vibration-absorbing, pivotable side handle
Vibration-absorbing grip
2.5 Protective devices
Mechanical safety clutch
Electronic restart interlock to prevent the power tool starting unintentionally after an interruption in the electric supply
(see section 9 "Troubleshooting").
Additional ATC "Active Torque Control" (TE 70‑ATC/AVR and TE 80‑ATC/AVR)
2.6 Lubrication
Gearing and hammering mechanism with separate lubrication chambers
2.7 Active Vibration Reduction
The tool is equipped with the "Active Vibration Reduction" (AVR) system, which significantly reduces vibration.
TE 80-ATC/AVR also has a handle damping system.
2.8 LED indicators
Service indicator LED (see section "Care and maintenance")
Reduced-power indicator (depends on version): (Please refer to the "Operation" section.)
2.9 Items supplied
1
Power tool
1
Side handle
1
Grease
1
Cleaning cloth
1
Operating instructions
1
Hilti toolbox
2.10 Using extension cords
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 110-127 V
2.11 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.
14 AWG
75 ft
12 AWG
150 ft
en
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Te 70-atc/avrTe 80-atc/avrTe 70-avr

Table of Contents