installing your camera
COMMUNICATION PROTOCOL DIP SWITCH
SETTINGS (SW2)
*
Coaxial communication automatically detects signals, and so does not require a
separate communication setup process.
ON
ON
OFF
SW2
Protocol Settings
Select a communication protocol for the camera
No
Protocol
SW2-#1
1
AUTO DETECT
OFF
2
Samsung-T
OFF
3
Pelco-D
OFF
4
Pelco-P
OFF
5
Samsung-E
OFF
6
Panasonic
OFF
7
Vicon
OFF
8
Honeywell
OFF
9
AD
ON
10
GE
ON
11
BOSCH
ON
12
Reserved
ON
13
Reserved
ON
14
Reserved
ON
15
Reserved
ON
16
Reserved
ON
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No.
Baud Rate(BPS)
2,400
1
4,800
2
9,600
3
19,200
4
20_ installing your camera
SW2 Pin No.
Purpose
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Response Mode Settings
8
Termination Settings
SW2-#2
SW2-#3
SW2-#4
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
SW2-#5
SW2-#6
ON
ON
ON
OFF
OFF
OFF
OFF
ON
Communication Response Settings
Select a communication response method for the camera and controller: Response or
No Response.
Function
SW2- #7
Response Mode Switch
Termination Settings
To prevent the attenuation of communication signals between the camera and
controller, the items at the end of line must be set up with the termination settings.
Camera Input Position
Termination of Longest Path
On the Path
*
This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.
M
To use a third party controller with this product, please contact our After-Sales Service
or Technology Department.
Controls Using Different Protocols
AD Protocol
Entering Camera OSD
3+Auxilary ON
Exiting Camera OSD
3+Auxilary OFF
ENTER
IRIS OPEN
ESC
IRIS CLOSE
Control with the SSC-5000 Controller
Protocol
Samsung-T
Samsung-E
Iris Open/Focus Far
Note that LCD monitor does not switch to OSD mode and the Joystick will not provide
Enter operation, when using the OSD menu with Samsung-E protocol.
CAMERA ID DIP SWITCH SETTINGS (SW1)
To set up camera IDs, refer to the "Camera ID Chart" next.
ON
SW1
ON
OFF
Response
No Response
SW2- #8
ON
OFF
VICON Protocol
GE Protocol
IRIS OPEN
IRIS OPEN
IRIS CLOSE
IRIS CLOSE
IRIS OPEN
IRIS OPEN
IRIS CLOSE
IRIS CLOSE
Enter
Esc
Focus Far
Focus Near
Iris Open/Focus Near
ON
OFF
English _ 21
English

Advertisement