Installer Qualifications
A licensed professional must install the appliance,
inspect it, and leak test it before use. The warranty
will be voided due to improper installation.
The installer should have skills such as:
Gas sizing.
Connecting gas lines, water lines, valves, and
electricity.
Knowledge of applicable national, state, and
local codes.
Installing venting through a wall or roof.
Training in installation of tankless water heaters.
(Training can be accessed on-line at
www.trainingevents.rinnai.us)
Type of installation
For installation in residential and commercial
domestic hot water applications only. (The unit is
not permitted for installation in hydronic heating
applications of any type.)
Certified for installation in manufactured (mobile)
homes.
Installation Steps
Prepare for Installation ...................................... 5
Determine Installation Location ......................... 6
Mount to Wall .................................................. 12
Remove the Front Panel .................................. 12
Condensate (indoor models only) .................... 37
(indoor models only) ........................................ 37
Installation of Plumbing ................................... 38
Checklist for Plumbing ..................................... 40
Installation of Gas Supply ................................. 46
Connect Electricity ........................................... 47
Adjustment for High Altitude ........................... 48
(indoor models only) ........................................ 48
Checklist for Gas and Electricity ....................... 48
Final Checklist................................................... 50
4

Installation Instructions

(for the licensed professional)

General Instructions

DO NOT
MUST DO
Do not install the RUR98i outdoors.
Do not install the RUR98e indoors.
Do not electronically manifold (MSB/EZ connect)
multiple units together.
Do not install the appliance in an area where water
leakage of the unit or connections will result in
damage to the area adjacent to the appliance or to
lower floors of the structure. When such locations
cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict
combustion air flow.
Do not obstruct the flow of combustion and
ventilation air. Combustion air shall not be
supplied from occupied spaces.
Do not use this appliance in an application such as
a pool or spa heater that uses chemically treated
water . (This appliance is suitable for filling large or
whirlpool spa tubs with potable water.)
Do not use substitute parts that are not authorized
for this appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The appliance and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.5 kPa)
(13.84 in W.C.).