Active Scan Region for the MS700i and MS715i Scanner

The active scan region is the region within the depth of field of the five scan
segments in which the laser beam can intercept and read symbols oriented as
shown in the section Symbol Orientation page 22. Planes formed by each of
the five scan segments define the bottom of the region. The 178mm (7.0")
depth of field of each of the scan segments bound the top. Best first pass read
will be observed for symbols that pass through the optimal scan area along a
1½ inch wide track centered in the defined region shown in Figure 6. Optimal
scan area range is 18mm - 160mm (.7" - 6.3").
Figure 6
23