Combustion Chamber
Room temperature
Power Lamp
Fuel Tank
Figure 4: Overview of Heater design
If heater does not start, the thermo stat setting may be too low.
Push "TEMP CONTROL UP ARROW" to higher setting to start
heater. If heater still does not start, see Troubleshooting Chart on
page 14.
NOTE: The major electrical components of this heater are protect-
ed by a circuit breaker (fuse) mounted to the power switch. If your
heater fails to start, check this first and replace as necessary. You
should also check your power source to insure that proper voltage
and frequency are being supplied to the heater.
TO STOP HEATER
Never unplug heater while heater is
WARNING
running!
Heater must go through cooling cycle. The cooling cycle cools the
combustion chamber. Damage to heater can occur if combustion
chamber is not cooled. Do not restart heater until cooling cycle is
complete.
1. Push "OPERATION BUTTON", This will cause heater flame to
go out. The motor will continue to run during the cooling cycle.
This allows the fan to cool the combustion chamber. When the
cooling cycle (approx. 2 minutes) is finished, the motor will stop.
Do not unplug heater until cooling cycle is finished.
2. Disconnect heater from power source.
Operation Button
Temp Control Buttons
Figure 5: Control Panel
© 2014 Pinnacle Products International, Inc.
Operation (Continued)
Fan
Motor
Control Panel
Operation Button
Fuse Barrel
Fuse
3. To temporarily stop heater, set thermostat at a temperature
lower than air around heater. Heater will cycle back on if air
temperature around heater matches thermostat setting.
TO RESTART THE HEATER
Do not restart heater until cooling cycle is
CAUTION
finished.
1. Wait until after cooling cycle has finished after stopping heater.
2. Repeat steps under TO START HEATER.
ELECTRICAL OUTLET
WARNING
Shock Hazard!
- Never plug in an appliance with more than 5amp rating in this
outlet.
- Always keep outlet covered when not in use
- 120V 5amp max (non fused).
Figure 6: Electrical Outlet
7
Kerosene User's Manual
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING OR WHILE CONNECTED
TO A POWER SOURCE
MODEL
MH-600T-KFA
Internal Shut-Off
176°F / 80°C
Temp. +/-10
Degrees
Reset Temp.
149°F / 65°C
+/-10 Degrees
Electrical Outlet
120v 5 amp max
(non-fused)