Dell Storage Center sc100 Owner's Manual page 30

Expansion enclosure
Table of Contents

Advertisement

Back-Panel Connectors (per EMM)
SAS connectors
Serial connector
LED Indicators
Front panel
Hard-drive carrier
EMM
Power supply/cooling
fan
Power Supplies
AC power supply (per power supply)
Wattage
Voltage
Heat dissipation
Maximum inrush current Under typical line conditions and over the entire system ambient operating
Available Hard Drive Power (per Slot)
Supported hard drive
power consumption
(continuous)
EMM Power (per Slot)
Maximum power
consumed by EMM
Maximum available
power
Maximum available
power
30
SAS A and B connectors for connecting an expansion enclosure to a storage
system.
NOTE: SAS connectors are SFF-8086/SFF-8088 compliant
One 6-pin UART mini-DIN connector
NOTE: Not for customer use.
One two-color LED indicator for system status
One single-color LED indicators for power status
One single-color activity LED
One two-color LED status indicator per drive
Three two-color LED status indicators, one each for the two EMM SAS ports
and one for the EMM status
Three LED status indicators for power supply status, power supply/cooling
fan fault status, and AC status
700 W
100–240 VAC (8.6–4.3 A)
SC100: 191–147 W
SC120: 133–114 W
range, the inrush current may reach 55 A per power supply for 10 ms or less
SC100: Up to 1.16 A at +5 V, up to 1.6 A at +12 V
SC120: Up to 1.2 A at +5 V, up to 0.5 A at +12 V
SC100: 11 W at +12 V
SC120: 14 W at +12 V
100 W at +12 V
1 W at +5 V (standby)
SC100/SC120 Technical Specifications