Epson Stylus Photo R220 Service Manual page 65

Hide thumbs Also See for Stylus Photo R220:
Table of Contents

Advertisement

EPSON Stylus Photo R220/R230
External View
Holder, Scale, Left
E Ring Flat
Washer
E Ring
Flat Washer Spring
Washer
Tabs
Cam, CR Left
Figure 2-26. Carriage Unit Removal (2)
DISASSEMBLY / ASSEMBLY
Holder, Scale, Right
Fixed Spring,
CR Shaft, Right
E Ring
Tab
Cam, CR Right
CR Guide Shaft
CR Guide Shaft
8.
Remove the E Ring, the Holder, Scale Right and the Cam, CR Right from the
right side of the CR Guide Shaft.
9.
Remove the Fixed Spring, CR Shaft, Right from the tab of the Frame, Main.
Then, remove the Fixed Spring, CR Shaft, Right from the CR Guide Shaft.
10. Remove the E ring and the Flat Washer that secure the Holder, Scale Left.
11. Remove the E Ring, the Flat Washer and the Spring Washer from the left side
of the CR Guide Shaft. Then, remove the Holder, Scale Left.
12. Release the Cable, Head from the 4 tabs of the Holder, Shaft Assy.
13. Slide the CR Guide Shaft to the right and pull it out from the Cam, CR Left.
Then, remove the Carriage Unit and the CR Guide Shaft together.
14. Pull the CR Guide Shaft out of the Carriage Unit.
Disassembly
Revision A
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stylus photo r230

Table of Contents