. ELECTRICAL EQUIPMENT
CURRENTD LEAKAGE TEST
Turn the ignition switch "OFF".
Remove the battery cover.
Disconnect the negative (-) cable from the
battery.
Connect the ammeter (+) probe to the
negative (-) cable and the ammeter (-) probe
to the battery (-) terminal.
With the ignition switch "OFF", check for
current leakage.
• When measuring current using a tester,
set it to high range, and then bring the
range down to an appropriate level.
Current flow higher than the range
selected may blow out the fuse in the
tester.
• While measuring current, do not turn
the ignition switch "ON". A sudden
surge of current may blow out the fuse
in the tester.
Specified current leakage: 1mA maximum
If current leakage exceeds the specified
value, a shorted circuit is likely.
Locate the short by disconnecting
connections one by one and measuring the
current.
16-7