E ec 1,' ca ©on ect
Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect
power.
2. Remove the hold-down screw and terminal block cover.
A
B
Style 1: Power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down,
and hold in place. Tighten strain relief screws just enough to
hold the two clamp sections together.
I1 n
\
C
"- .... ;.....................................
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
A. Center terminal block screw
B. Hold-down
screw
C. Terminal block cover
D. Internal ground conductor screw
3. Install strain relief.