SYMPTOM
Water separator warning system comes on:
• Water separator warning buzzer sounds.
PGM-FI warning system comes on:
• PGM-FI indicator comes on.
• PGM-FI warning buzzer sounds intermittently.
ACG warning system comes on:
• ACG indicator comes on.
• ACG warning buzzer sounds intermittently.
POSSIBLE CAUSE
Water is accumulated in the water
separator.
PGM-FI warning system is faulty.
Battery voltage is too high or low.
Faulty ACG.
TROUBLESHOOTING
REMEDY
Clean the water separator (see page
138).
Check the fuel tank and fuel line for
water accumulation. If the buzzer
sounds again, consult with an
authorized Honda outboard motor
dealer.
Consult with an authorized
Honda outboard motor dealer.
Check the battery (see page 134).
Consult with an authorized
Honda outboard motor dealer.