Nomad 55
View looking down on to chassis (as if looking down through the cabinet)
Partial View Of Chassis
AC Receptacle
Footswitch DIN plug
TUBE TASK CHART
NOTE: Before changing tubes, turn the POWER SWITCH to the off
position or to STANDBY. CAUTION..Tubes are HOT when they have
been in use.
(Each 12AX7 contains two separate Triodes)
B A
B A
V 4
V 5
6L6
REAR OF CHASSIS
Description of Tube Functions
V1 A & B = (paralleled) input stage
V2 A = 2nd Stage Channel 1
V2 B = 3rd Stage Channel 1
V3 A = 4th Stage Channel 2 & 3
V3 B = 3rd Stage Channel 2 & 3
12AX7
B A
B A
V 2
V 3
6L6
V4 A = 2nd Stage Channel 2 & 3
V4 B = FX Return Stage
V5 A & B = Phase Inverter
B A
V 1