rS-485/422
Configure the controller connection so that the camera's PTZ can be controlled using the
controller connected to the camera's RS-485/422 terminal.
1. From the Setup menu, select the
<ptZ (
)> tab.
2. Click <rS-485/422>.
3. Click <▼ Show>.
4. Specify the serial port.
The communication protocol used by
the controller connected to the network
camera can be set (RS-485/422).
• Protocol : Select the same protocol
version as the controller, choosing
from SAMSUNG-T / SAMSUNG-E /
PELCO-D / PELCO-P / PANASONIC
/ HONEYWELL / AD / VICON / GE /
BOSCH.
• Camera ID : Set the camera ID (1-255).
• Baudrate : Set the RS-485/422 communication speed.
5. When done, click [apply (
For this operation, the network camera and controller must be properly connected. Also, the
`
M
controller must have a serial port set to control the camera.
There may be functions that are not supported depending on the controller or protocol
J
`
specifications. Please see the following table for details.
)].
English _87