Burner And Nozzle Specifications - Hotpoint G640SW Operating Instructions Manual

Table of Contents

Advertisement

Burner and nozzle specifications

Table 1
Burner
Diameter
(mm)
Rapid (R)
94
Semi Rapid (S)
69
46
Auxiliary (A)
Supply
pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
Model
Class
G640SK
II2H3+
7,80 (567 g/h - G30) (557 g/h - G31)
G640SX
G640SW
(1)
The values in g/h refer to the capacities with liquid gas (Butane, Propane).
S
S
R
A
G640SW
G640SX
G640SK
Thermal Power
By-pass
kW (p.c.s.*)
1/100
(mm)
Nominal Reduced
3.00
0.70
39
1.90
0.40
28
1.00
0.40
28
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
Gas section
(1)
Rated power (kW)
Liquid Gas
Natural Gas
Nozzle
Flow*
Nozzle
1/100
g/h
1/100
(mm)
(mm)
***
**
87
218
214
128
70
138
136
104
52
73
71
76
28-30
37
20
25
35
45
Electric section
Voltage and frequency
Power (W)
220-240V~ 50/60Hz
Flow*
l/h
286
181
95
20
17
25
0,6