Wiring; Remote Connection; Paralleling Generator Sets - Kohler 40-150EOZDJ Installation Manual

Marine generator sets
Table of Contents

Advertisement

Kohler Co. recommends using one 12-volt battery (or
two for 24-volt systems, as the spec requires) to start the
generator. See Figure 6-5 for minimum cold cranking
amps (CCA) recommendations.
12-Volt Starting Battery Size CCA
at - -18C (0F) or 100 Amp. Hr.
Models
40EOZDJ and 33EFOZDJ
40EOZCJ and 33EFOZCJ
40EFOZDJ
40EFOZCJ
50EFOZDJ
50EFOZCJ
55EOZDJ and 45EFOZDJ
55EOZCJ and 45EFOZCJ
65EOZDJ and 55EFOZDJ
65EOZCJ and 55EFOZCJ
80EOZDJ and 70EFOZDJ
80EOZCJ and 70EFOZCJ
99EOZDJ and 80EFOZDJ
99EOZCJ and 80EFOZCJ
125EOZDJ and 100EFOZDJ
125EOZCJ and 100EFOZCJ
150EOZDJ and 125EFOZDJ
150EOZCJ and 125EFOZCJ
Figure 6-5 Battery Recommendations

6.6 Wiring

Use only stranded copper wire. Conform to USCG
Regulations 183.425 through 183.460 for wire gauges
and insulation, conductor temperature ratings, sheath
stripping, conductor support and protection, conductor
terminals and splices, and over-current protection
(circuit breakers, fuses). Use rubber grommets and
cable ties as necessary to protect and secure the wire
from sharp objects, the exhaust system, and moving
parts.

6.7 Remote Connection

Kohler Co. offers several remote panels for connection
to the generator set.
distributor/dealer for detailed descriptions. Kohler Co.
also offers wiring harnesses in various lengths with a
connector keyed to the controller box connector.
"pigtail" harness is also offered which includes the
appropriate connector on one end and has pigtails that
the installer can use to connect to a customer-supplied
start/stop switch or separate lights and hourmeter.
Consult wiring diagrams, ADVs, and instruction sheets
for connection information/details.
TP-6862
6/14
CCA
640
625
925
Contact your local Kohlerr
Note: Gauge senders. Gauge senders are available
for most generator sets.
supplied gauges, be sure they are compatible
with generator set senders.
authorized Kohlerr service distributor/dealer.
Gauges and senders are available as service
items from an authorized Kohlerr service
distributor/dealer.
Various
wiring
harnesses, remote control panels, and remote
annunciator panels are available.

6.8 Paralleling Generator Sets

See Section 9 for information on paralleling generator
sets.
A
If using customer-
Contact an
harnesses,
Y-connectors,
Section 6 Electrical System
pigtail
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

40-150eozcj33-125efozdj33-125efozcj

Table of Contents