Baxi Solo 3 30 PF User Operating Instructions Manual page 6

Wall mounted powered flue gas fired central heating unit

Advertisement

5mm
350mm (30,40,50 models)
462mm (60,70,80 models)
50mm
600mm
100mm
Fig. 7
6
5mm during operation
5mm
287mm
300mm for servicing
4.0 Clearances
4.1
Clearances around the boiler (Fig. 7)
1. The minimum clear spaces needed around the
boiler are:
Top:
50mm (2 in)
Bottom: 100mm (4 in)
Sides:
5mm (
3
/
in)
16
Front:
5mm (
3/
in)
16
2. These clearances must not be obstructed in
any way. Blocking the clearance spaces will
result in the appliance overheating and
possible damage may occur.
3. The boiler may be installed in a cupboard if
these minimum clearances are kept. Note that the
label affixed to the front of the boiler must be left in
place to ensure future servicing is successfully
undertaken.
4. The compartment should be large enough to
house the boiler and ancillary equipment only.
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
6. The gas burning compartment of your boiler is
completely sealed from the room in which it is
fitted. Products from the combustion of gas are
vented to the outside through the flue terminal
which must be kept free from obstruction as this
would interfere with the correct operation of the
boiler.