Your Baxi Solo is a gas fired, room sealed,
fan-assisted, central heating boiler providing
heating for your home and domestic hot
water where required.
*

THERMOSTAT KNOB

To shut down the boiler
turn fully anti-clockwise
Fig. 2

2.0 Operating the Boiler

2.1
Operating the Boiler
1. Remove lower door panel as shown (Fig. 1).
2. Turn the boiler thermostat knob to the '0'
position fully anti-clockwise (Fig. 2).
3. Turn on the main gas and electricity supplies
to the appliance.
4. Set the thermostat control knob to the
required setting. (The optimum boiler setting
depends upon type of system, external controls
and your requirements. Your installer will be able
to advise you on this matter.)
5. The fan will start to run and after a short
period of time the ignition spark will commence.
Sparking will continue until the pilot flame is
established then stop automatically. The main
gas will then come on and the burner will light
from the pilot flame. Check that both the main
burner and the pilot are alight by looking through
the viewing window. The bottom four indicator
lights should also be illuminated (Fig. 3).
2.2
To shut down the boiler
1. Turn off the electricity supply to the appliance
at the mains.
2. Turn the thermostat knob to zero (Fig. 2) then
turn off the gas supply at either the appliance
gas cock or the meter.
2.3
Frost Protection
1. The appliance incorporates a frost protection
thermostat that will light the appliance when it's
temperature falls to near freezing. Note that this
is designed to protect the boiler only - the
system pipework may require the protection of
an additional stat.
2. To set the appliance to frost protection but
without normal heating. Set the control knob to
*
the
position (Fig. 2).
3. The frost protection will only operate if gas
and electrical supplies are switched on.
*