Attached accessories.

No.
Accessories part
Installation plate
1
Installation plate fixing
screw
2
Remote control
3
Battery
4
SELECT THE BEST LOCATION
INDOOR UNIT
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place
where noise
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall be
at least 2.5 m.
OUTDOOR UNIT
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Piping size
Model
Gas
Liquid
PC9DKV
3/8"
1/4"
PC12DKV
1/2"
1/4"
Qty.
1
5
1
2
prevention
is taken
Max.
Max. Piping
Additional
Elevation
Length
Refrigerant
(m)
(g/m)
(m)
-
5
7
-
5
7
Indoor/Outdoor Unit Installation Diagram
Indoor/Outdoor Unit Installation Diagram
Length of power supply cord
About 1.1 m
About 1.8 m
< <
<
<
5 cm
or more
(Left and right are identical)
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape
into
CU-PC12DKV
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
- 27 -
CS-PC9DKV / CU-PC9DKV / CS-PC12DKV / CU- PC12DKV
Piping direction
Attention not to
(Front side)
bend up drain hose
Right
Right Rear
Left
Right Bottom
Left
Rear
Left Bottom
Installation parts you
should purchase ( )
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn't break.
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
CU-PC9DKV
Saddle ( )
Connecting cable
(3-CORE WIRE/1.5mm ( )
Type designation 245 IEC 57
or heavier cord
Additional drain hose ( )
1/4" Liquid side piping (
Gas side piping ( )
CS/CU-PC9DKV :
CS/CU-PC12DKV :
2
)
3/8"
1/2"