Attach ed access ories

Attached accessories.

No.
Accessories part
Qty. No.
Installation plate
1
1
Installation plate fixing
screw
5
2
Remote control
1
3
Battery
2
4
SELECT THE BEST LOCATION
INDOOR UNIT
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
ıA place where drainage can be easily done.
ıA place
where noise
consideration.
ıDo not install the unit near the door way.
ıEnsure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
ıRecommended installation height for indoor unit shall be
at least 2.5 m.
OUTDOOR UNIT
ıIf an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Piping size
Elevation
Model
Gas
Liquid
PC12DK
1/2"
1/4"
PA12DKD
1/2"
1/4"
Accessories part
Qty.
Drain elbow
(Only for PA12DKD)
1
5
Connecting Wire (Connector)
(Only for PA12DKD)
1
6
prevention is taken
Max. Piping
Max.
Additional
Length
Refrigerant
(m)
(m)
(g/m)
5
7
-
5
7
-
Indoor /Outdo or Unit Installa tion Diagra m
Indoor/Outdoor Unit Installation Diagram
Length of power supply cord
About 1.1 m
About 1.8 m
< <
<
<
5 cm
or more
(Left and right are identical)
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape
into
ı ı ı
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
33
CS-PC12DKD/ CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Piping direction
Attention not to
(Front side)
bend up drain hose
Right
Right Rear
Left
Right Bottom
Left
Rear
Left Bottom
Installation parts you
should purchase ( )
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn't break.
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle ( )
Connecting cable
(3-CORE WIRE/1.5mm
PC12DKD
(5-CORE WIRE/1.5mm
2
+2X0.5mm )-
Type designation 245 IEC 57
or heavier cord
Additional drain hose ( )
1/4" Liquid side piping (
Gas side piping ( ) 1/2"
2
( )-
)
2
( )
PA12DKD
)