Removing the electrodes

6
Supplied By www.heating spares.co Tel. 0161 620 6677
1. Remove rubber gasket "G" (see fig. 1.11) ;
2. Disconnect ignition leads by pulling downward (see fig. 1.12) ;
3. To remove the flame sensor disconnect the cable at its only connection
point close to the P.C.B. (see fig. 1.13) ;
G
Fig. 1.11
5. Remove screw "H" using a Philips No. 2 star tip screwdriver (see fig. 1.14) ;
6. Slide the electrode gently downward (see fig. 1.15).
H
Fig. 1.14
To replace, repeat the steps in reverse order, paying particular attention to the
following:
a - Centre the electrode in the positioning hole carefully, otherwise the
electrode may break;
b -Check that the cables have been connected correctly;
c - Check that the rubber gasket covers the cable/electrode connection
point completely.
Fig. 1.12
Fig. 1.15
Fig. 1.13