TC/UB SET Menu

TC/UB SET
Menu items
Timecode
Setting the
timecode
Users Bit
Setting the user
bits
TC Format
Setting the time
code format

OTHERS Menu

OTHERS
Menu items
All Reset
Resetting to the
factory status
Camera Data
Storing/recalling
the menu settings
Time Zone
Setting the time
difference
110
Setup Menu List
Subitems and setting values Contents
Mode
Preset / Regen / Clock
Run
Rec Run / Free Run
Setting
Reset
Execute / Cancel
Mode
Fix / Date
Setting
DF / NDF
Subitems and setting values Contents
Execute/Cancel
Store
Execute/Cancel
Recall
Execute/Cancel
UTC –12:00 to +14:00
Set the timecode mode.
Preset: To start the timecode from the specified value
Regen (regeneration): To continue the timecode from that of
the previous clip
Clock: To use the current clock time as the timecode
Set the running mode when the timecode mode is set to
"Preset."
Rec Run: The timecode advances only in recording mode.
Free Run: The timecode keeps advancing regardless of
recording.
Set the timecode to a desired value.
Select "SET" to finish the setting.
Select "Execute" to reset the timecode to 00:00:00:00.
Set the user bit mode.
Fix: To use a desired fixed value as the user bits
Date: To use the current date
Set the user bits to a desired value.
Set the timecode format.
DF: Drop frame
NDF: Non drop frame
Select "Execute" to reset the camcorder to the factory status.
Select "Execute" to store the setting values in an SxS memory
card.
Select "Execute" to retrieve the setting values from an SxS
memory card.
Set the time-zone difference from UTC in steps of 30
minutes.
Note
The default setting is different among the sales areas.
United States and Canada: –5:00
Europe area: 0:00
Oceania: +10:00