Technical Data
Hand-Held Sprayer (Models: 16N661, 16N662, 16N663, 16N667, 16P122, 16W104)
Maximum Amperage
Adjustable Pressure Range
Fixed Pressure
Maximum Working Pressure
Weight
Dimensions:
Length
Width
Height
Storage Temperature Range
Operating Temperature Range
Storage Humidity Range
Sound Pressure Level
Vibration Level Acceleration
Power Cord
Electrical Power Requirement
Pump damage will occur if fluid freezes in pump.
Damage to plastic parts may result if impact occurs in low temperature conditions.
Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.
† per ISO 3744 measured at 3.3 feet (1m)
†† per ISO 5349, no load condition
3A2854G
U.S. (Customary)
2 Amps
1000 - 2000 psi
1300 psi
2000 psi
6.04 lb
6.86 lb (15 ft cord)
12.75 in.
5.5 in.
10.75 in.
32° to 113° F
40° to 90° F
0% to 95% relative humidity,
non-condensing
70.5 dBa† (for sound power level,
add 81.5 dBa)
2
Less than 2.2 feet/s
18 AWG, 3-wire, 18 in.
18 AWG, 3-wire, 15 ft
220/240 Vac, 50 Hz, 10A, 1 phase
Metric
2 Amps
7 - 14 MPa, 69 - 138 bar
9.9 MPa, 89.6 bar
14 MPa, 138 bar
2.74 kg
3.11 kg (4.6 m cord)
32.4 cm
14.0 cm
27.3 cm
0° to 45° C
4° to 32° C
0% to 95% relative humidity,
non-condensing
70.5 dBa† (for sound power level,
add 81.5 dBa)
2
Less than 0.67 m/s
††
2
1.0 mm
, 3-wire, 46 cm
2
1.0 mm
, 3-wire, 4.6 m
220/240 Vac, 50 Hz, 10A, 1 phase
Technical Data
29