Download Print this page

GE GTDX400ED Dimensions And Installation Information page 2

6.0 cu. ft. capacity duradrum electric dryer

Advertisement

GTDX400ED
GE
6.0 cu. ft. capacity DuraDrum
®
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-
rigid) ducting can be used (Kit WX08X10077). In special installations, it may be
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid
metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter
can be maintained throughout the entire length of the transition duct. Please see
installation instruction packed with your dryer for complete instructions when using
flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the
duct length should be treated as a 90° elbow. A turn over 45° should be treated as a
90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust
into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or
any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
GE Dryer Vent
electric dryer
Dryer Exhausting Information — Use Metal Duct Only
Vertical and Horizontal Ducting
A
4
Domestic dryer models
All Long Vent 6.0 - 8.3 cu. ft.
capacity electric & gas dryers
(GTDL, GFDL)
All 6.0 - 8.3 cu. ft. capacity
models electric and gas dryers
(GFDS, GFDR, GFDN, GTDS,
GTDN, GHDN, GHDS, GTDP,
GLDP, GTDX, HTDP, HTDX)
DCVH480
All 3.6 cu. ft. (DSKS, DSKP)
electric dryers
Laundry Center GTUP270,
GTUN275
Laundry Center GTUP240
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to
the chart.
The total vent system length includes all the straight
portions and elbows of the system (transition duct included).
Laundry Center length includes factory-installed elbow that
does not impact vent length.
GE Dryer Vent
Best performance
A
Maximum length
of 4" dia rigid
A
4
metal duct
B
Exhaust hood type
A
Number
2-1/2
of 90°
4"
B
turns
opening
0
150 ft.
2-1/2
1
135 ft.
2
125 ft.
3
115 ft.
4
105 ft.
5
95 ft.
0
90 ft.
1
60 ft.
2
45 ft.
3
35 ft.
4
25 ft.
0
90 ft.
1
60 ft.
2
45 ft.
3
35 ft.
0
46 ft.
1
37 ft.
2
30 ft.
3
23 ft.
0
56 ft.
1
48 ft.
2
40 ft.
3
32 ft.
0
43 ft.
1
33 ft.
2
24 ft.
B
2-1/2"
opening
125 ft.
115 ft.
105 ft.
95 ft.
85 ft.
75 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
60 ft.
45 ft.
35 ft.
25 ft.
37 ft.
30 ft.
22 ft.
15 ft.
42 ft.
34 ft.
26 ft.
18 ft.
36 ft.
26 ft.
16 ft.
Specification Revised 3/14