INSTALLATION INSTRUCTIONS
TECHNICAL DATA
Gas connection
Pressure test point
Gas rate adjustment
Aeration adjustment
Electrical connection
Professional 60
CH60DPCF S CH60DPXF S
BURNER
HOTPLATE
Front Left
HOTPLATE
Rear Right
HOTPLATE
Front Right and Rear Left
TOTAL LOAD
Traditional 60
CH60DTXF S S CH60DTCF S
BURNER
HOTPLATE
Front Left and Rear Right
HOTPLATE
Front Right and Rear Left
TOTAL LOAD
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
8
Rp ½ (½" BSP female)
Front left hotplate injector
None
None
4mm
twin and earth
2
230/240V a.c. 50Hz.
HEAT INPUT
4.1 kW
3.05 kW
2.0 kW
HEAT INPUT
3.05 kW
2.0 kW
G20 at 20mbar
INJECTOR
100+72+100
116
103
4.5 / 4.9 kW
G20 at 20mbar
INJECTOR
116
103
4.5 / 4.9 kW
G30 at 28-30mbar
G31 at 37mbar
HEAT INPUT
INJECTOR
3.8 kW (275g/h)
63+42+63
3.0 kW (220g/h)
2.0 kW (145g/h)
G30 at 28-30mbar
G31 at 37mbar
HEAT INPUT
INJECTOR
3.0 kW (220g/h)
2.0 kW (145g/h)
86
70
86
70