Service Done By Authorised Océ Technician - Oce CS9090 User Manual

Low solvent
Hide thumbs Also See for CS9090:
Table of Contents

Advertisement

Chapter 7: Maintenance
7.3 SERVICE DONE BY AUTHORISED OCÉ TECHNICIAN
This section describes the periodical services required for this machine.
The periodical services ensure stable printout quality of the machine.
In the periodical services, some service parts may be checked, cleaned, or replaced.
Perform periodical inspections according to the table below.
Quantity
10
8
11
2
12
4x0,8m
13
1 + 1m + 1
14
1
15
1
16
as required
17
as required
18
as required
19
as required
20
as required
Maintenance
Cycle
1
10
11
12
13
14
15
16
17
18
19
20
Notes
All cleaning in "Ink areas" must be done with Océ low solvent cleaning solution.
Above maintenance cycle is based on use:
8 hours / day, 5 days / week and 44 weeks / year.
If machine is used more, maintenance periods will come earlier.
AP-75036 - Revision 1.3 – 20/03/06
Action
Change dampers
Change pumps (*)
Change tubes from pumps -> Waste bottle
Change spitting box + tube + L connection
Change capping station
Change cap assy maintenance station
Apply grease on head up-down cams when needed
Apply grease on Y-motor belt when needed
Apply grease on roller path – carriage when needed (**)
Apply grease on capping station camm + gears when needed
Dust removal in fan area underneath print platform
2
3
4
Month
5
6
7
x
x
x
x
x
x
x
x
x
x
158
8
9
10
User's Guide CS9000 series
11
12
x
x
x
x
x
x
x
x
x