Power supplies

The x3850 X6 server supports up to four redundant power supplies. Standard models come with one, two,
or four power supplies (model dependent). The following table lists the power supplies.
Table 18. Power supplies
Part number
Feature code
44X4150
A54D
44X4152
A54E
44X4132
A4R0
88Y7433
A2EA
An AC power supply ships standard with one 2.8 m C13 - C14 power cord.
Configuration rules are as follows:
Power supplies must be in pairs (x3850 X6) or quads (x3950 X6), with the exception of model
3837-A4x, where one power supply is supported.
The AC power supplies can be mixed. Valid combinations for the x3850 X6 for example, are:
Two 44X4132 and two 44X4152
Two 44X4132 and two 44X4150
It is not recommended you mix the two 1400 W options (44X4152 for low altitude and 44X4150 for
high altitude) as you will nullify the high-altitude capabilities of 44X4150.
You cannot mix the AC power supplies with the DC power supply
Use the Power Configurator to determine exactly what power your server needs:
http://ibm.com/systems/bladecenter/resources/powerconfig.html

Integrated virtualization

The server supports VMware ESXi that is installed on a USB memory key. The key is installed in a USB
socket that is on the primary I/O book inside the server. The following table lists the virtualization options.
Table 19. Virtualization options
Part number
Feature
code
41Y8298
A2G0
41Y8382
A4WZ
IBM System x3850 X6
Description
IBM 1400W HE Redundant Power Supply
for altitudes >5000 meters
IBM 1400W HE Redundant Power Supply
IBM 900W Power Supply
IBM 750W High Efficiency -48 V DC Power
Supply
Description
IBM Blank USB Memory Key for VMware ESXi Downloads
IBM USB Memory Key for VMware ESXi 5.1 U1
Maximum
Models
supported
where used
x3850 X6
4
A7x, A8x,
A9x,
All HANA
models
4
-
4
A4x, B1x,
B3x,
C1x, C4x
4
-
Maximum
supported
1
1
32