Maytag JDB4000AWB Technical Information page 3

Maytag dishwasher service manual
Table of Contents

Advertisement

Component Specifications
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing,
unless testing requires power.
Illustration
Limit Thermostat
Sensor/Thermistor
Heater/Heating
Element
120v/60hz, 650 watts
± 5% in air, 830 watts
± 5% in coldwater
Drain Motor
120v/60hz
May 2004
©2004 Maytag Services
!
Component
Close on Temperature drop @ 149°F
± 7°F (Temp) ......................................
Open on Temperature drop @ 164°F
± 4°F (Temp) ......................................
10KΩ ± 3% at 77°F and 2.4 k Ω ±
6.5% at 140°F
J5 pin 1 - Orange (Temp) to J5 Pin 4 -
Red (Neutral) .....................................
Measure resistance from ST1
Red/Black (Heater) to ST11 White
(Common) ..........................................
Measure resistance from
ST6 Gray (Drain) to ST4 Black
(Common) ..........................................
See section "Motor Connections and
Diagram" for wiring contacts.
WARNING
Test Procedure
3
Results
0 Ω
= Closed
Infinite Ω = Open
Infinite Ω = Open
0 Ω
= Closed
16 Ω
(This value assumes the high limit
thermostat is closed).
25 Ω
16023063

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents