Appendix A Event Notification Message List
A.2 Message List
A.2.2
Error Messages
This section describes the messages that are sent when the severity is Error for each type of
event.
■
Error message list
●
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature
error is detected.
Event type
and event
P 01SSMM00 2
P 06SSMM00 2
P 08SSMM0p 2
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
Sensor
code
No.
0100MM00
0600MM00
0800MM0p
Copyright 2014 FUJITSU LIMITED
Upper: Message
Trap
Lower: Description
Info
-
Controller Module#m(zz xxHz) Fault
<pppppppppppp ssssssssss rrrrr>
CM is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz xxHz) BE Expander
Fault <pppppppppppp ssssssssss rrrrr>
CM EXP is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz xxHz) DI Port#p Fault
<pppppppppppp ssssssssss rrrrr>
CM DI Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
96
Remarks
These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.
P3AM-5512-07ENZ0