Item
Slot
Display form
Counter of Digital
Trunk Error Logs
logged in "Minor
Error" Log
Counter of minor
communication error
(ANSI T1 403-1999)
Notes
• If the port type of PRI23 card is assigned to "EXT" by System Programming, the
detailed information cannot be displayed on this screen.
• "Counter of minor communication error" is displayed only when the LPR software
version of the corresponding cards is the following.
T1 card: "Y311D" or later
PRI23 card: "Q361AB" or later
Installation Manual
Description
Blank (default)
All
Card No.: Type (The T1/PRI23 card installed in the system is
displayed automatically.)
past 24 hours/in 1 hour segments
past 24 hours/in 30 min segments
past 24 hours/in 10 min segments
past 2 weeks/in 1 day segments
Out of SYNC (#1318): Digital trunk out of sync
RAI (#1319): Digital trunk RAI signal reception
AIS (#1320): Digital trunk AIS signal reception
Frame Failure (#1323): Digital trunk frame failure
Multi Frame Failure (#1324): Digital trunk multi frame failure
Error Rate Over (#1325): Digital trunk error rate over
DSP Link Failure (#1328): DSP-1 link failure
CRC: CRC error
SF: Severely error frame (Available for PRI23 card only)
FE: Frame synchronization bit-error
LV: Line-code violation
SL: Controlled Slip
Description
Utility
265